| Period |
Run file |
User |
DAQ code |
Analysis code |
| May '12 |
S412_ |
profi, agata |
mbsrun/agatadaq/april_2012/frs_alone |
/u/profi/Go4/s412_MM |
Hardware information
| TA |
S1 |
S2 |
S3 |
S8 |
Seetram 9Be TA2 |
(degrader) |
degrader,air,FingerSCI(1mm),TPC23,TPC24 |
- |
SC81(1mm) |
Technical problems
1. Target 2 station: value for the drive TS2ET2HS had to be put manually.
2. Driver of degrader at S1 did not work neither via SD program nor in manual mode. The motor moved, but there was no connection to the gear drive. A piece of Al (4.9 mm) was inserted then in the detector pocket.
3. lxg1031 crashed, thus remote event server and DAQ run on lxg1033.
4. Degrader at S2, drive TS3ED7V moved manually. Later one, after entering in S2 a loose contact was found. TS3ED7DS had similar problems.
5. MW21 left and right signals were switched, cables changed in the Messhütte.
» Summary
|
|
|
Comments? Questions? Error reports? Please contact the
webmaster!
The FRS web pages have been accessed 26971 times since October 27, 2003!