Operational Modes of the Low Pressure Gas System                                                                  

Normal Operation

 

Low Pressure Operation (20 – 1000 mbar)

Vacuum Operation

V1

closed

V1

open

V1

open

V2

open

V2

closed

V2

closed

V3

open

V3

closed

V3

closed

V4

closed

V4

normally closed/open only for rapid pumping

V4

open

V5

open

V5

closed

V5

closed

V6

open

V6

closed

V6

closed

V7

open

V7

open

V7

open

V8

open

V8

open

V8

open

V9

open

V9

open

V9

open

V10

open

V10

open

V10

open

LV1

closed

LV1

open/preset*

LV1

closed

MKS 640

off

MKS 640

on/preset**

MKS 640

off

Rotary Pump

off

Rotary Pump

on

Rotary Pump

on

                                                                                                                                                                                          

                                                                                                                                                                                          

*  = Gas Flow Preset                                                                                                                                                           

** = Pressure Preset (see Calibration Table)                                                                                                                           

                                                                                                                                                                                          

In the Normal Operation Mode the Gas Flow for the Detectors CG01 and CG02  is controlled only at the Ar/CO2 Gas Distribution Rack                

                                                                                                                                                                                          

Before venting the Target Area be sure that the Low Pressure Gas System is set into the

Normal Operational Mode to avoid bouncing of the pocket windows!


 